Description: Transfer belt start signal error - Definition - [B] The transfer belt start signal is not detected within 500 ms relative to the programmed timing.
Causes: • IPU board defective • DIP SW301-1 on the IPU board is not ON
Description: Laser synchronizing signal error - Definition - [B] The intervals between laser synchronizing signals become over 1.2 times the normal interval.
Causes: • Laser synchronizing detector board defective • Scanner control board defective • Laser synchronizing detector board not properly positioned • LD unit defective
Description: Bk-development motor lock - Definition - [B] The Bk-development motor lock signal is detected for more than 3 seconds.
Causes: • Bk-development motor defective or poor connection • Too much load on the Bk-development section • Interface board 1 defective or poor connection (CN708) • Main control board defective
Description: Bk-sleeve motor lock - Definition - [B] The Bk-sleeve motor lock signal is detected for more than 3 seconds.
Causes: • Bk-sleeve motor defective or poor connection • Too much load on the Bk-sleeve roller • Interface board 1 defective or poor connection (CN708) • Main control board defective
Description: Y-sleeve motor lock - Definition - [B] The Y-sleeve motor lock signal is detected for more than 3 seconds.
Causes: • Y-sleeve motor defective or poor connection • Too much load on the Y-sleeve roller • Interface board 2 defective or poor connection (CN806) • Main control board defective
Description: M-sleeve motor lock - Definition - [B] The M-sleeve motor lock signal is detected for more than 3 seconds.
Causes: • M-sleeve motor defective or poor connection • Too much load on the M-sleeve roller • Interface board 2 defective or poor connection (CN806) • Main control board defective
Description: C-sleeve motor lock - Definition - [B] The C-sleeve motor lock signal is detected for more than 3 seconds.
Causes: • C-sleeve motor defective or poor connection • Too much load on the C-sleeve roller • Interface board 2 defective or poor connection (CN806) • Main control board defective
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.