Description: Waste toner bottle motor error
The lock signal of the waste toner bottle motor remains HIGH for more than 600 ms.
Causes: • Waste toner bottle motor defective
Code: SC487
Description: Waste toner bottle set error
The set sensor of the waste toner bottle remains LOW for more than 500 ms. (The sensor goes HIGH when the bottle is installed correctly.)
Causes: • Install the waste toner bottle • Remove waste toner bottle and reinstall correctly
Code: SC488
Description: Waste toner transport lock
Waste toner cannot be transported to the waste toner bottle.
Causes: • Blockage in the line to the waste toner bottle
Code: SC496
Description: MUSIC sensor error
The MUSIC sensor detected an abnormal pattern on the ITB because: • ADC exceeded upper or lower limit. • The pattern used to calculate the amount of skew is abnormal. • The reading of the pattern exceeded the length of time the LED projected light. • LED light could not be adjusted correctly.
Causes: • MUSIC sensor defective or disconnected • MUSIC pattern abnormal; do a forced process control (SP3821) and check the result (section 4.2.4).
Code: SC497
Description: Temperature and humidity sensor error 1: PCU
The thermistor output of the temperature and humidity sensor above the black PCU was not within the prescribed range (0.5V to 4.2V)
Causes: • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective
Code: SC498
Description: Temperature and humidity sensor error 2
The thermistor output of the temperature and humidity sensor at below the waste toner bottle was not within the prescribed range (0.5V to 4.2V)
Causes: • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective
Code: SC503
Description: Tray 1 feed error
• The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate. • When the tray lowers, the tray lift sensor does not go off within 1.5 sec.
Causes: • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle
Code: SC504
Description: Tray 2 feed error
• The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate. • When the tray lowers, the tray lift sensor does not go off within 1.5 sec.
Causes: • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle