Code :
  • Code: SC422
  • Description: Potential sensor error 3: Vd Adjustment C
    The development potential of the drum before exposure (Vd) cannot be adjusted to within ±10 V of the target voltage 900V).
  • Causes: • Toner density low
  • Code: SC423
  • Description: Potential sensor error 4: Vd Adjustment Y
    The development potential of the drum before exposure (Vd) cannot be adjusted to within ±10 V of the target voltage 900V).
  • Causes: • Toner density low
  • Code: SC424
  • Description: Potential sensor error 5: Vl adjustment K
    Vpl could not be adjusted to within ±10V of the target Vpl after exposure of the ID sensor patterns.
  • Causes: • Toner density low
  • Code: SC425
  • Description: Potential sensor error 6: Vl adjustment M
    Vpl could not be adjusted to within ±10V of the target Vpl after exposure of the ID sensor patterns.
  • Causes: • Toner density low
  • Code: SC426
  • Description: Potential sensor error 7: Vl adjustment C
    Vpl could not be adjusted to within ±10V of the target Vpl after exposure of the ID sensor patterns.
  • Causes: • Toner density low
  • Code: SC427
  • Description: Potential sensor error 8: Vl adjustment Y
    Vpl could not be adjusted to within ±10V of the target Vpl after exposure of the ID sensor patterns.
  • Causes: • Toner density low
  • Code: SC432
  • Description: Potential sensor error 1: Vr K
    Vr > 200V The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
  • Causes: • Toner density low
  • Code: SC433
  • Description: Potential sensor error 2: Vr M
    Vr > 200V The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
  • Causes: • Toner density low