Description: Potential sensor error 3: Vd Adjustment C
The development potential of the drum before exposure (Vd) cannot be adjusted to within ±10 V of the target voltage 900V).
Description: Potential sensor error 4: Vd Adjustment Y
The development potential of the drum before exposure (Vd) cannot be adjusted to within ±10 V of the target voltage 900V).
Description: Potential sensor error 5: Vl adjustment K
Vpl could not be adjusted to within ±10V of the target Vpl after exposure of the ID sensor patterns.
Description: Potential sensor error 6: Vl adjustment M
Vpl could not be adjusted to within ±10V of the target Vpl after exposure of the ID sensor patterns.
Description: Potential sensor error 7: Vl adjustment C
Vpl could not be adjusted to within ±10V of the target Vpl after exposure of the ID sensor patterns.
Description: Potential sensor error 8: Vl adjustment Y
Vpl could not be adjusted to within ±10V of the target Vpl after exposure of the ID sensor patterns.
Description: Potential sensor error 1: Vr K
Vr > 200V The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
Description: Potential sensor error 2: Vr M
Vr > 200V The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
Causes: • Toner density low
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.