Description: Potential sensor error 3: Vr C
Vr > 200V The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
Causes: • Toner density low
Code: SC435
Description: Potential sensor error 4: Vr Y
Vr > 200V The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
Causes: • Toner density low
Code: SC436
Description: Potential sensor error 5: Vd K
The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -700)
Description: Potential sensor error 6: Vd M
The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -700)
Description: Potential sensor error 7: Vd C
The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -700)
Description: Potential sensor error 8: Vd Y
The VdHome reading, the first step of the process control self-check, detected that the development potential of the unexposed areas of the drum are not within the prescribed range (-500 to -700)
Description: Image transfer power pack error 1: K
An interrupt checks the status of the power pack every 2 ms. This SCis issued if the BCU detects a short in the power pack for K, M, C, or Y 250 times within 500 ms.
Causes: • Transfer belt damaged, insulation damaged • Insulation on high voltage cable damaged • Another hot point inside the machine has damaged insulation • Insulation around high-voltage power supply damaged • IOB damaged
Code: SC441
Description: Image transfer power pack error 2: M
An interrupt checks the status of the power pack every 2 ms. This SCis issued if the BCU detects a short in the power pack for K, M, C, or Y 250 times within 500 ms.
Causes: • Transfer belt damaged, insulation damaged • Insulation on high voltage cable damaged • Another hot point inside the machine has damaged insulation • Insulation around high-voltage power supply damaged • IOB damaged