Code: SC191

Description: Bar code scan error - Timing - When the main switch is turned on - Condition - The main scanner IPU board detects that the pattern of the bard code scanned in is not appropriate.
Causes: • Non-standard bar code label • Improper location of bar code • Dirty bar code • Defective main scanner IPU board • Defective main control board
Remedy: 1. Check if the bard cord is damaged or scratched. 2. Clean the optics section such as mirrors and lens and bar code. 3. Check if the mirrors are properly set on the 1st and 2nd scanners. If the spring plate, which is fix the position of mirrors, is out of position, it causes light axis to be changed. 4. Replace the main scanner IPU board. 5. Replace the main control board.

Code: SC192

Description: Bar code number mismatch - Timing - When the main switch is turned on - Condition - The main control board detects that the bar code data scanned in does not match to the machine identification number stored in the RAM.
Causes: • Defective RAM board • Defective main scanner IPU board • Defective main control board
Remedy: 1. Check if the serial number stored in the RAM is correct. NOTE: Contacts your product specialist for the detailed procedure. 2. Replace the main scanner IPU board. 3. Replace the main control board.

Code: SC193

Description: IDU error - Timing - When the main switch is turned on - Condition - The IDU starts diagnosing at power-on and any hardware error is detected during diagnostics.
Causes: • Defective IDU • Defective sub/main scanner IPU board
Remedy: 1. Perform the scanner IPU board test (SP 4-904-001 and 002). If not OK, replace the main and/or scanner IPU board. SP 4-904-001 or 002 0: OK 25 or 35: Replace sub scanner IPU board. Others: Replace main scanner IPU board. 2. Replace the IDU board.

Code: SC195

Description: Serial number error - Timing - When the main switch is turned on - Condition - The serial number entered or stored in RAM is not correct.
Causes: • Improper serial number • RAM board is replaced. • Defective RAM
Remedy: 1. Check and re-enter the serial number properly. NOTE: Contacts your product specialist for the detailed procedure.

Code: SC301

Description: Charge current leak - Timing - When the main charge is ON in the printing process or process control mode - Condition - The current leak is detected for 2 seconds.
Causes: • Charge corona unit not installed properly • Poor connection of harnesses • Defective high voltage supply board (C/G/B) • Defective I/O control board • Defective main control board.
Remedy: 1. Reinstall the charge corona unit properly or replace the charge corona unit. 2. Reconnect the connectors on the high voltage supply board (C/G/B), I/O control board, and main control board, or check the harnesses. 3. Check and clean the charge corona unit receptacle. 4. Replace the high voltage supply board (C/G/B). 5. Replace the I/O control board. 6. Replace the main control board. [ Signal Check ] • Leak detection: CN217-7 or TP120 on I/O control board

Code: SC302

Description: Charge corona grid voltage error - Timing - When the main charge grid is ON in the printing process or process control mode - Condition - The feedback voltage is 4.8V or higher, or PMW value is 50% or higher for 500msec continuously.
Causes: • Charge corona unit not installed properly • Poor connection of harnesses • Defective high voltage supply board (C/G/B) • Defective I/O control board • Defective main control board.
Remedy: 1. Reinstall the charge corona unit properly or replace the charge corona unit. 2. Reconnect the connectors on the high voltage supply board (C/G/B), I/O control board, and main control board, or check the harnesses. 3. Check and clean the charge corona unit receptacle. 4. Replace the high voltage supply board (C/G/B). 5. Replace the I/O control board. 6. Replace the main control board. [ Signal Check ] • Leak detection: CN217-7 or TP120 on I/O control board [ Signal Check ] • Feedback signal: CN217-5, TP173, or CN211-A6 on I/O control board or CN302-A4 or TP107 on main control board • PWM: CN217-6 or TP140 on I/O control board

Code: SC303

Description: Charge cleaner motor error - Timing - When the charge cleaner starts - Condition - • Over-current is detected for 10 seconds when the cleaner pads start moving from rear to front. • Over-current is still not detected 1 minute after the cleaner motor turns on.
Causes: • Poor connection of connector • Defective cleaner motor • Cleaner pad locked • Defective I/O control board • Defective main control board
Remedy: 1. Check if the connectors (CN861 & CN829) are firmly connected. 2. Check if the charge corona unit is properly set. 3. Clean the screw shaft if it is dirty. 4. Check if the cleaner pad is mechanically locked. 5. Check if the connector is firmly connected on the I/O control board (CN219). 6. Replace the I/O control board. 7. Replace the main control board.

Code: SC320

Description: Polygon motor error - Condition - • The polygon motor rotation speed stays out of the range 22 seconds after the main switch is turned on. • The polygon motor rotation speed becomes out of the range while the main switch is ON. (Polygon motor keeps rotating with constant speed while the main switch is ON.)
Causes: • Poor connection of connector • Defective polygon motor • Defective LD control board • Defective main scanner IPU board
Remedy: 1. Check the connector (CN602-5) on the LD control board is properly connected. 2. Check the continuity of harness. 3. Replace the polygon motor. 4. Replace the LD control board. 5. Replace the main scanner IPU board. [ Signal Check ] • Motor OK: CN602-2 on LD control board.