Các lỗi thường gặp

Code :
  • Code: 401
  • Description: Transfer roller leak error (positive electrode)
    The feedback voltage of the transfer roller is insufficient.
  • Causes: • Defective high voltage supply board
    • Loose connection of the PCU
    • Incorrect installation of the transfer unit or the separation unit
    • Defective transfer roller
  • Code: 402
  • Description: Transfer roller leak error (negative electrode)
    The feedback voltage of the transfer roller is insufficient.
  • Causes: • Defective high voltage supply board
    • Loose connection of the PCU
    • Incorrect installation of the transfer unit or the separation unit
    • Defective transfer roller
  • Code: 500
  • Description: Main motor error
    A main motor lock signal is not detected for more than 7 consecutive checks (700 ms) after the main motor starts to rotate, or the lock signal is not detected for more than 7 consecutive checks during rotation after the last signal.
  • Causes: - Too much load on the drive mechanism
    - Main motor defective
  • Code: 502
  • Description: Tray 2 lift motor malfunction (Optional paper tray units)
    The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds.
  • Causes: - Paper lift sensor defective
    - Tray lift motor defective
    - Too much load on the drive mechanism
    - Poor tray lift motor connection
  • Code: 503
  • Description: Tray 3 lift motor malfunction (optional paper tray units)
    The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds.
  • Causes: - Paper lift sensor defective
    - Tray lift motor defective
    - Too much load on the drive mechanism
    - Poor tray lift motor connection
  • Code: 504
  • Description: Tray 4 lift motor malfunction (optional two-tray paper tray unit)
    The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds.
  • Causes: - Paper lift sensor defective
    - Tray lift motor defective
    - Too much load on the drive mechanism
    - Poor tray lift motor connection
  • Code: 506
  • Description: Paper feed motor lock (optional paper tray units)
    A motor lock signal is not detected for more than 1.5 s or the lock signal is not detected for more than 1.0 s during rotation.
  • Causes: - Paper feed motor defective
    - Too much load on the drive mechanism
  • Code: 541
  • Description: Fusing thermistor open (center)
    The fusing temperature detected by the thermistor is below 71C and is not corrected after the main power switch is turned on.
  • Causes: - Fusing thermistor defective or out of position
    - Power supply board defective
    - Loose connectors