Description: Startup without video output end error
Video transfer to the engine is started, but the engine did not issue a video transmission end command within the specified time.
Causes: - Controller board defective
Code: 804
Description: Startup without video input end
A video transmission was requested from the scanner, but the scanner did not issue a video transmission end command within the specified time.
Causes: - Controller board defective
Code: 818
Description: Watchdog error
The CPU does not access the watchdog register within a certain time.
Description: Self-Diagnostic Error: CPU
The central processing unit returned an error during the self-diagnostic test.
Causes: - Controller board defective
- Download controller firmware again
Code: 821
Description: Self-Diagnostic Error: ASIC
The ASIC returned an error during the selfdiagnostic test because the ASIC and CPU timer interrupts were compared and determined to be out of range.