Description: Image transfer error
The controller is not able to transfer images when the engine needs them.
Causes: - Application program defective
Code: 964
Description: Status error (laser optics housing unit)
The optics-housing unit does not become ready within 17 seconds after the request.
Causes: - Software defective
Code: 981
Description: NVRAM error
The machine detects a discrepancy in the NVRAM write/read data when attempting to save actual data to the NVRAM (i.e. during actual use).
Causes: - NVRAM defective
- Poor connection between BICU and NVRAM
- NVRAM is not connected
- BICU defective
Code: 982
Description: Localization error
The localization settings in the nonvolatile ROM and RAM are different
Causes: - First machine start after the NVRAM is replaced
- Incorrect localization setting
- NVRAM defective
Code: 984
Description: Print image transfer error
Print images are not transferred.
Causes: - Controller defective
- BICU board defective
- Poor connection between controller and BICU
Code: 990
Description: Software performance error
The software attempted to perform an unexpected operation
Causes: - Software defective
- Internal parameter incorrect
- Insufficient working memory
- When this SC occurs, the file name, address, and data will be stored in NVRAM. This information can be checked by using SP 7403. Note the above data and the situation in which this SC occurs. Then report the data and conditions to your technical control center.
Code: 991
Description: Software continuity error
The software attempted to perform an unexpected operation. However, unlike SC990, the object of the error is continuity of the software.
Causes: - No operation required. This SC code does not appear on the panel, and is only logged.
Code: 992
Description: Unexpected Software Error
Software encountered an unexpected operation not defined under any SC code.
Causes: - Software defective
- An error undetectable by any other SC code occurred