Các lỗi thường gặp

Code :
  • Code: 546
  • Description: Unstable fusing temperature (center)
    The fusing temperature varies 50° C or more within 1 second, and this occurs 2 consecutive times.
  • Causes: • Thermistor defective or out of position
    • Power supply unit defective
  • Code: 547
  • Description: Zero cross signal malfunction
    Zero cross signals are not detected within 5 seconds after the main power switch is turned on, or are not detected within 1 second after operation begins.
  • Causes: • Power supply board defective
    • BICU defective
  • Code: 551
  • Description: Fusing thermistor open (rear)
    The fusing temperature detected by the thermistor is below 71°C and is not corrected after the main power switch is turned on.
  • Causes: - Fusing thermistor defective or out of position
    - Power supply board defective
    - Loose connectors
  • Code: 552
  • Description: Fusing temperature warm-up error (rear)
    The fusing temperature rises less than 7 degrees in 2 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 25 or 35 seconds.
  • Causes: - Fusing thermistor defective or out of position
    - Fusing lamp open
    - Power supply board defective
  • Code: 553
  • Description: Fusing overheat error (rear)
    The fusing temperature is over 230°C for 1 second (detected by the thermistor).
  • Causes: - Fusing thermistor defective
    - Power supply board defective
  • Code: 555
  • Description: Fusing lamp overheat error (rear)
    After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 20 consecutive seconds.
  • Causes: - Fusing thermistor defective or out of position
    - Power supply board defective
  • Code: 556
  • Description: Unstable fusing temperature (rear)
    The fusing temperature varies 50°C or more within 1 second, and this occurs 2 consecutive times.
  • Causes: - Thermistor defective or out of position
    - Power supply unit defective
  • Code: 559
  • Description: Jam error detected 3 times in succession
    The exit sensor and the duplex sensor detect a paper jam 3 times in succession This condition can occur when SP 1159 1 is set to ‘on’. The default is ‘off’.
  • Causes: Paper jams can occur for the following reasons.
    • Dampness
    • Paper curl
    • Incorrect paper setting in the paper tray
    • Stripper pawls coming apart