Các lỗi thường gặp

Code :
  • Code: 590
  • Description: Left exhaust fan motor error
    The CPU detects an exhaust fan lock signal for more than 5 seconds.
  • Causes: • Loose connection of the exhaust fan motor
    • Too much load on the motor drive
  • Code: 591
  • Description: Rear exhaust fan motor error
    The CPU detects an exhaust fan lock signal for more than 5 seconds.
  • Causes: • Loose connection of the exhaust fan motor
    • Too much load on the motor drive
  • Code: 620
  • Description: Communication error between BICU and ADF
    The BICU does not receive a response from the ADF main board for 4 seconds or more. The BICU receives a break signal from the ADF main board.
  • Causes: • Poor connection between the BICU and
    ADF main board (DF connector)
    • ADF main board defective
    • BICU defective
  • Code: 621
  • Description: ADF connection error
    An incorrect ADF (an ADF for some other copier) is detected.
  • Causes: • ADF incorrect (The ADF for B039/B040/ B043 or B121/B122/B123/B259/ B260/B261 is installed on a B282/B283)
    • The connector of the ADF is removed while the machine is in the energy saver mode
  • Code: 632
  • Description: Accounting error 1
    An error is detected during the communication with the MF accounting device.
  • Causes: - Accounting device defective
    - Loose connection
  • Code: 634
  • Description: Accounting RAM error
    An error is detected in the RAM that saves the information on the MF accounting.
  • Causes: - Accounting device defective
  • Code: 635
  • Description: Accounting battery error
    An error is detected in the battery that is in the MF accounting device.
  • Causes: Accounting device defective
  • Code: 692
  • Description: Controller board communication abnormal
    Communication error between the printer part of the controller board and BICU.
  • Causes: • The connector is abnormal between the controller board and the BICU board.