Các lỗi thường gặp

Code :
  • Code: 694
  • Description: Controller board communication abnormal
    Communication error between the scanner part of the controller board and BICU.
  • Causes: • The connector is abnormal between the controller board and the BICU board.
  • Code: 760
  • Description: ADF gate abnormal 1
    The ADF Gate signal line between the ADF main board and the BICU is disconnected.
  • Causes: • ADF main board defective
    • Input/output board defective
    • Poor connection (ADF Gate line) between the ADF main board and the BICU.
  • Code: 761
  • Description: ADF gate abnormal 2
    The FGATE signal is not issued from the ADF within 30 seconds after the ADF starts feeding.
  • Causes: • ADF connector defective
    • SBU board defective
  • Code: 762
  • Description: ADF gate abnormal 3
    The FGATE signal is not terminated by the ADF within 60 seconds after the ADF starts feeding.
  • Causes: • ADF connector defective
    • SBU board defective
  • Code: 903
  • Description: Engine total counter error
    The checksum of the total counter is not correct.
  • Causes: • NVRAM on the BICU defective
  • Code: 928
  • Description: Memory error
    The machine detects a discrepancy in the write/read data during its write/read test (done at power off/on and at recovery from low power or night/ off mode).
  • Causes: • Memory defective
    • BICU defective
    • Poor connection between BICU and memory
  • Code: 929
  • Description: IMAC hardware error
    A memory control job is not completed within a certain period.
  • Causes: • BICU defective
    • Poor connection
  • Code: 981
  • Description: NVRAM error
    The machine detects a discrepancy in the NVRAM write/ read data when attempting to save actual data to the NVRAM (i.e. during actual use).
  • Causes: • NVRAM defective
    • Poor connection between BICU and NVRAM
    • NVRAM is not connected
    • BICU defective