Mã lỗi Ricoh Aficio MP1900 — Trang 4/5

Code: 552

Description: Fusing temperature warm-up error (rear)
The fusing temperature rises less than 7 degrees in 2 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 25 or 35 seconds.
Causes: - Fusing thermistor defective or out of position
- Fusing lamp open
- Power supply board defective

Code: 553

Description: Fusing overheat error (rear)
The fusing temperature is over 230°C for 1 second (detected by the thermistor).
Causes: - Fusing thermistor defective
- Power supply board defective

Code: 555

Description: Fusing lamp overheat error (rear)
After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 20 consecutive seconds.
Causes: - Fusing thermistor defective or out of position
- Power supply board defective

Code: 556

Description: Unstable fusing temperature (rear)
The fusing temperature varies 50° C or more within 1 second, and this occurs 2 consecutive times.
Causes: - Thermistor defective or out of position
- Power supply unit defective

Code: 559

Description: Jam error detected 3 times in succession
The exit sensor and the duplex sensor detect a paper jam 3 times in succession This condition can occur when SP 1159 1 is set to 'on'. The default is 'off'.
Causes: - Paper jams can occur for the following reasons.
- Dampness
- Paper curl
- Incorrect paper setting in the paper tray
- Stripper pawls coming apart

Code: 590

Description: Left exhaust fan motor error
The CPU detects an exhaust fan lock signal for more than 5 seconds.
Causes: - Loose connection of the exhaust fan motor
- Too much load on the motor drive

Code: 621

Description: ADF connection error
An incorrect ADF (an ADF for some other copier) is detected.
Causes: ADF incorrect (The ADF for B039/B040/B043 or B121/B122/B123 is installed on this machine.)

Code: 760

Description: ADF gate abnormal 1
The ADF Gate signal line between the ADF main board and the BICU is disconnected.
Causes: - ADF main board defective
- Input/output board defective
- Poor connection (ADF Gate line) between the
- ADF main board and the BICU.