Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio MP1900 — Trang 5/5

Code: 761

Description: ADF gate abnormal 2
The FGATE signal is not issued from the ADF within 30 seconds after the ADF starts feeding.
Causes: - ADF connector defective
- SBU board defective

Code: 762

Description: ADF gate abnormal 3
The FGATE signal is not terminated by the ADF within 60 seconds after the ADF starts feeding.
Causes: - ADF connector defective
- SBU board defective

Code: 901

Description: Mechanical total counter
The mechanical total counter does not work properly.
Causes: - Mechanical total counter defective
- BICU defective
- Disconnected mechanical total counter

Code: 903

Description: Engine total counter error
The checksum of the total counter is not correct.
Causes: - NVRAM on the BICU defective

Code: 928

Description: Memory error
The machine detects a discrepancy in the write/read data during its write/read test (done at power off/on and at recovery from low power or night/off mode).
Causes: - Memory defective
- BICU defective
- Poor connection between BICU and memory

Code: 929

Description: IMAC Hardware Error
Causes:

Code: 981

Description: NVRAM error
The machine detects a discrepancy in the NVRAM write/read data when attempting to save actual data to the NVRAM (i.e. during actual use).
Causes: - NVRAM defective
- Poor connection between BICU and NVRAM
- NVRAM is not connected
- BICU defective

Code: 982

Description: Localization error
The localization settings in the nonvolatile ROM and RAM are different (SP5807). The download (program, print data, language data) from the IC card does not execute normally.
Causes: Board installed incorrectly BICU board defective IC card defective NVRAM defective Loss of power during downloading Important Notes About SC999 Primarily intended for operating in the download mode, logging is not performed with SC999. If the machine loses power while downloading, or if for some other reason the download does not end normally, this could damage the BICU or the PCB targeted for the download and prevent subsequent downloading. If this problem occurs, the damaged PCB must be replaced.