Code: 321

Description: No laser writing signal (F-GATE) error
The laser-writing signal (F-GATE) fails to turn Low after the laser crosses 5 mm on the drum surface from the laser writing start position.
Causes: • BICU board defective
• Controller defective

Code: 322

Description: Laser synchronization error
The main scan synchronization detector board cannot detect the laser synchronization signal for more than 5 consecutive 100 ms intervals.
Causes: • Poor connection between the LD unit and the BICU board
• Damaged cable between BICU and LD unit
• LD unit out of position
• LD unit defective
• BICU board defective

Code: 390

Description: TD sensor error
The TD sensor outputs less than 0.2 V or more than 4.0 V 10 times consecutively during copying.
Causes: • TD sensor abnormal
• Poor connection of the PCU

Code: 391

Description: Development bias leak
A development bias leak signal is detected.
Causes: • Poor connection of the PCU
• High voltage supply board defective

Code: 392

Description: Developer initialization error
The ID sensor does not detect a correct pattern during developer initialization.
Causes: • Seal in the PCU not removed
• Defective ID sensor
• Defective TD sensor
• Defective drum operation
• Defective development roller operation
• Loose connection of the PCU
• Insufficient voltage for the charge roller

Code: 401

Description: Transfer roller leak error 1 (positive electrode)
A current leak signal for the transfer roller is detected. A current feedback signal for the transfer roller is not detected.
Causes: • High voltage supply board defective
• Poor connection of the PCU
• Transfer/separation unit set incorrectly
• Transfer roller damaged

Code: 402

Description: Transfer roller leak error 2 (negative electrode)
A current leak signal for the transfer roller is detected. A current feedback signal for the transfer roller is not detected.
Causes: • High voltage supply board defective
• Poor connection of the PCU
• Transfer/separation unit set incorrectly
• Transfer roller damaged

Code: 500

Description: Main motor lock
A main motor lock signal is not detected for more than 7 consecutive checks (700 ms) after the main motor starts to rotate, or the lock signal is not detected for more than 7 consecutive checks during rotation after the last signal.
Causes: • Too much load on the drive mechanism
• Main motor defective