Các lỗi thường gặp

Code :
  • Code: 503-01-11
  • Description: Paper bank 1 error (Paper Feed Unit or LCT) (Paper lift error) (D158/D159)
    The paper lift sensor fails to activate after the tray lift motor has been on for 18 seconds
  • Causes: • Paper lift sensor • Tray lift motor • Poor tray lift motor connection • Broken harness • Defective bank controller board
  • Code: 503-02-12
  • Description: Paper bank 1 error (Paper Feed Unit or LCT) (Upper limit error) (D158/D159)
    The paper lift sensor fails to activate three times continuously right after the tray lift motor has been turned on.
  • Causes: • Paper lift sensor • Broken harness • Defective bank controller board
  • Code: 504
  • Description: Tray 4 error (D160/D161/D170)
    The paper lift sensor fails to activate three times continuously after the tray lift motor has been on for 18 seconds.
  • Causes: • Paper lift sensor • Tray lift motor • Broken harness • Defective bank controller board
  • Code: 504-01-11
  • Description: Paper bank 2 error (Paper Feed Unit or LCT) (Paper lift error) (D158/D159)
    The paper lift sensor fails to activate after the tray lift motor has been on for 18 seconds.
  • Causes: • Paper lift sensor • Tray lift motor • Broken harness • Defective bank controller boardnds.
  • Code: 504-02-12
  • Description: Paper bank 2 error (Paper Feed Unit or LCT) (Upper limit error) (D158/D159)
    The paper lift sensor fails to activate right after the tray lift motor has been turned on.
  • Causes: • Paper lift sensor • Broken harness • Defective bank controller board
  • Code: 508
  • Description: By-pass bottom plate error
    The signal from the by-pass tray HP sensor does not change for 1.0 second after the by-pass motor has rotated counterclockwise. If this condition occurs three consecutive times, the SC is generated.
  • Causes: • Disconnect or defective harness of the by-pass motor • Defective or disconnected connection for the by-pass motor.
  • Code: 520
  • Description: Registration motor error
    When the registration motor is rotating
  • Causes: • Motor lock • Defective motor driver
  • Code: 521
  • Description: Bank transport motor error (D160/D161/D170)
    The error code occurs when the optional paper tray unit (D698) is installed.
  • Causes: • Defective bank transport motor • Loose connection • Defective bank controller board