Code :
Tất cả lỗi
101 101-01 101-02 102 120 121 141 142 144 161-01 161-02 165 195 202 203 204 220 230 231 240 270 302 320 321 322 350 351 353 354 355 389 390 391 392 440 460 490 501 502 503 503-01-11 503-02-12 504 504-01-11 504-02-12 508 520 521 521-01-11 530 531 532 541 542 542-01 542-03 543 544 545 547 547-01 547-02 547-03 551 552 552-01 552-03 553 554 555 557 559 590 591 620 621 622 632 634 635 669 681 687 692 694 701-03 701-08 702-01 702-02 702-03 760 901 903 928 929 981 982 995
Code: 521-01-11
Description: Bank transport motor error (D158/D159) An error code is issued from the paper bank unit.
Causes: • Defective bank transport motor • Loose connection • Disconnected or broken harness • Defective bank controller board
Code: 530
Description: Fusing fan error (D158/D159)
Causes:
Code: 531
Description: QSU fan error (D158/D159)
Causes:
Code: 532
Description: CTL fan error (D158/D159) Lock signal is not issued for more than 50 consecutive 100 ms intervals, during fan is rotating.
Causes: • Motor overload • Loose connection
Code: 541
Description: Fusing thermistor open (center) The fusing temperature is below 0°C for 5 seconds (detected by the thermistor).
Causes: • Fusing thermistor defective or out of position • Loose connectors
Code: 542
Description: Fusing reload failed (center) (D160/D161/D170) NOT reaching the reload temperature in 20 ms after starting fusing lamp control.
Causes: • Defective thermistor • Disconnected fusing lamp
Code: 542-01
Description: Fusing reload failed (center) (D158/D159) The fusing temperature rises less than 4 degrees in 2 seconds, and this continues 5 times consecutively.
Causes: • Fusing thermistor defective or out of position • Power supply board
Code: 542-03
Description: Fusing reload failed (center) (D158/D159) The fusing temperature does not reach the target within 28 seconds after the fusing lamp controller is activated.
Causes: • Broken fusing lamp cablester)