Description: Fusing reload failed (rear) (D160/D161/D170) NOT reaching the reload temperature in 20 ms after starting fusing lamp control.
Causes: • Defective thermistor • Disconnection of fusing lamp
Code: 552-01
Description: Fusing temperature warm-up error (rear) (D158/D159) The fusing temperature rises less than 4 degrees in 2 seconds, and this continues 5 times consecutively.
Causes: • Fusing thermistor defective or out of position • Power supply board
Code: 552-03
Description: Fusing temperature warm-up error (rear) (D158/D159) The fusing temperature does not reach the target with in 28 seconds after the fusing lamp controller is activated.
Causes: • Broken fusing lamp cables
Code: 553
Description: Fusing overheat error (rear) The fusing temperature is over 230°C for 1 second (detected by the thermistor).
Causes: • The triac has shorted out. • Defective BICU • Defective fusing control system
Code: 555
Description: Fusing lamp overheat error (rear) After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 20 consecutive seconds.
Causes: Fusing thermistor defective or out of position • Power supply board
Code: 557
Description: Zero cross frequency error (D158/D159) The detection error occurs 10 times or more in 11 frequency detections. This error is defined when the detected zero cross signal is more than 66.
Causes: • Caused by noise
Code: 559
Description: Jam error detected 3 times in succession The exit sensor and the duplex sensor detect a paper jam 3 times in succession This condition can occur when SP1-159-001 is set to ‘on’. The default is ‘off’.
Causes: • Paper jams can occur for the following reasons. • Dampness • Paper curl • Incorrect paper setting in the paper tray • Stripper pawls coming apart