Các lỗi thường gặp

Code :
  • Code: SC650-13
  • Description: Remote Service Modem Communication Error (RC Gate Type Mwas installed but modem is not present (detected during operation)) • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on. • Displayed only when an error is detected while RC Gate is operating. • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
  • Causes: RC Gate Type Mwas installed but modem is not present (detected during operation)
  • Remedy: • If a modem board is not installed, install it. • Check again if the modem driver configurations (SP5-816-160, SP5-816-165 to 171, SP5-816-165 to 171) are correct. • If the problem is not solved, replace the modem.
  • Code: SC650-14
  • Description: Remote Service Modem Communication Error (RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly) • An error related to communication (dialup connection, modem board etc.) using the RC Gate was detected or an error that prevents RC Gate operation was detected at power on. • Displayed only when an error is detected while RC Gate is operating. • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
  • Causes: RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly
  • Remedy: • If a modem board is attached, remove it. • Check if wired/wireless LAN works.
  • Code: SC651-01
  • Description: Illegal Remote Service Dial-up (Chat program parameter error) An unexpected error occurred when RC Gate Type M dialed up the NRS Center.
  • Causes: Software bug
  • Remedy: Logging only.
  • Code: SC651-02
  • Description: Illegal Remote Service Dial-up (Chat program execution error) An unexpected error occurred when RC Gate dialed up the NRS Center.
  • Causes: Software bug
  • Remedy: Logging only.
  • Code: SC652-00
  • Description: Remote service ID2 mismatching There was an authentication mismatch between ID2 for @Remote, the controller board, and NVRAM.
  • Causes: • Used controller board installed • Used NVRAM installed (such action is not allowed.)
  • Remedy: • If this occurs during RC Gate installation: Check the validity of the certificate and the NVRAM, check the machine serial number, write the common certificate, and then begin installation again. • If this occurs after RC Gate installation: Clear the RC Gate install status, check the validity of the certificate and the NVRAM, check the machine serial number, write the common certificate, and then begin installation again.
  • Code: SC653-00
  • Description: Incorrect remote service ID2 ID2 stored in the NVRAM has either of the following problems. • Number of characters is not 17. • Includes a character that cannot be printed. • All spaces • NULL
  • Causes: Replace the NVRAM.
  • Remedy: Clear the RC Gate install status, write the common certificate, and then begin installation again.
  • Code: SC669-01
  • Description: EEPROM OPEN: ID error
  • Causes: Received a error notification during EEPROM communication and doesnot resume after 3 retries. • Electrical noise • EEPROM not connected fully • EEPROM not installed • EEPROM damaged • BCU damaged
  • Remedy: • Turn the power off/on • Reconnect the EEPROM • Replace the EEPROM • Replace the BCU
  • Code: SC669-02
  • Description: EEPROM OPEN: Channel error
  • Causes: Received a error notification during EEPROM communication and doesnot resume after 3 retries. • Electrical noise • EEPROM not connected fully • EEPROM not installed • EEPROM damaged • BCU damaged
  • Remedy: • Turn the power off/on • Reconnect the EEPROM • Replace the EEPROM • Replace the BCU