Description: Communication timeout between SBCU and finisher: Error 1
The SBCU cannot receive a response within 100 ms after 3 attempts after sending data to the finisher.
Causes: • Serial line connecting SBCU and finisher unstable • External noise
Description: Communication timeout error between SBCU and duplex unit
The SBCU cannot receive a response within 1 sec. from the duplex unit.
Causes: • Serial line connecting SBCU and duplex unit unstable • External noise • SBCU board and duplex main board connection defective or loose • Duplex main board defective • SBCU board defective
Description: EEPROM Communication Error
The machine failed to detect a match between the read/write data for the EEPROM on the SBCU after 3 attempts.
Causes: • EEPROM installed incorrectly • EEPROM defective After you check the installation, turn the machine off and on. If this does not repair the problem, replace the SBCU.
Description: Controller-to-operation panel communication error at startup
After powering on the machine, the communication circuit between the controller and the operation panel is not opened, or communication with controller is interrupted after a normal startup.