Description: SBU connection error
The IPU does not detect the SBU connection signal.
Causes: Harness between SBU and IPU board loose, disconnected, or damaged.
Code: 165
Description: Copy Data Security Unit error
An error occurred when the machine attempted to recognize the Copy Data Security Unit board.
Causes: • The Copy Data Security Unit board is not installed • The Copy Data Security Unit board is installed, but it is not the correct type for the machine.
Code: 193
Description: Image transfer error
The IPU board does not finish within 1 minute after the image data has been transferred to the controller board.
Description: DFGATE assert error
The DFGATE signal does not assert within 30 seconds after the original has been scanned.
Causes: • ADF interface cable loose, disconnected, or damaged • SBCU defective • Mismatched firmware between the SBCU board and ADF
Code: 196
Description: DFGATE negate error
The DFGATE signal does not negate within 1 minute after the DFGATE has been asserted.
Causes: • ADF interface cable defective • SBCU defective • Mismatched firmware between the SBCU board and ADF
Code: 197
Description: DFGATE error
The DFGEATE signal has already been asserted at the original scan.
Causes: • ADF interface cable defective • SBCU board defective • Mismatched firmware between the SBCU board and ADF
Code: 198
Description: Memory address error
The IPU board does not receive the memory address from the controller board.
Causes: • Mismatched firmware between the SBCU board and controller board • Controller defective • SBCU defective • IPU board defective Note: Before you replace a board, update the firmware. This can repair the error.
Code: 199
Description: DF scanning finish error
The original does not finish scanning with in 1 minute
Causes: • ADF interface cable defective • SBCU board defective • Mismatched firmware between the SBCU board and ADF