Các lỗi thường gặp

Code :
  • Code: 144
  • Description: SBU connection error
    The IPU does not detect the SBU connection signal.
  • Causes: Harness between SBU and IPU board loose, disconnected, or damaged.
  • Code: 165
  • Description: Copy Data Security Unit error
    An error occurred when the machine attempted to recognize the Copy Data Security Unit board.
  • Causes: • The Copy Data Security Unit board is not installed • The Copy Data Security Unit board is installed, but it is not the correct type for the machine.
  • Code: 193
  • Description: Image transfer error
    The IPU board does not finish within 1 minute after the image data has been transferred to the controller board.
  • Causes: • IPU board defective • Controller board defective • Video controller defective
  • Code: 195
  • Description: DFGATE assert error
    The DFGATE signal does not assert within 30 seconds after the original has been scanned.
  • Causes: • ADF interface cable loose, disconnected, or damaged • SBCU defective • Mismatched firmware between the SBCU board and ADF
  • Code: 196
  • Description: DFGATE negate error
    The DFGATE signal does not negate within 1 minute after the DFGATE has been asserted.
  • Causes: • ADF interface cable defective • SBCU defective • Mismatched firmware between the SBCU board and ADF
  • Code: 197
  • Description: DFGATE error
    The DFGEATE signal has already been asserted at the original scan.
  • Causes: • ADF interface cable defective • SBCU board defective • Mismatched firmware between the SBCU board and ADF
  • Code: 198
  • Description: Memory address error
    The IPU board does not receive the memory address from the controller board.
  • Causes: • Mismatched firmware between the SBCU board and controller board • Controller defective • SBCU defective • IPU board defective Note: Before you replace a board, update the firmware. This can repair the error.
  • Code: 199
  • Description: DF scanning finish error
    The original does not finish scanning with in 1 minute
  • Causes: • ADF interface cable defective • SBCU board defective • Mismatched firmware between the SBCU board and ADF