Remedy: • Check the ADF cable connection • Replace the ADF • Replace the IPU board
Code: SC621
Description: Finisher communication error • Detected an error when connecting the communication line. • Received a communication error notification from the URAT.
Causes: • Finisher control board defective. • BCU defective • Connection fault between finisher and main machine.
Remedy: • Reconnect the Finisher interface cable • Replace the BCU • Replace the finisher • Turn the power off/on
Code: SC622
Description: Paper bank communication error • Detected an error when connecting the communication line. • Received a communication error notification from the URAT.
Causes: • Paper bank control board defective • BCU defective • Paper bank-main machine connection fault
Remedy: • Reconnect the optional paper tray connection cable • Replace the BCU • Replace the optional paper tray • Turn the power off/on
Code: SC632-00
Description: Counter device error 1 After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.
Causes: Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged.
Remedy: • Turn the main power off/on. • Check the serial communication line.
Code: SC633-00
Description: Counter device error 2 After communication was established, the controller received the brake signal from the accounting device.
Causes: Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged.
Remedy: • Turn the main power off/on. • Check the serial communication line.
Code: SC634-00
Description: Counter device error 3 A backup RAM error was returned by the counter device.
Causes: Counter device control board or the backup battery of counter device defective
Remedy: • Replace the counter device control board. • Replace the backup battery.
Code: SC635-00
Description: Counter device error 4 A backup battery error was returned by the counter device.
Causes: Counter device control board or the backup battery of counter device defective
Remedy: • Replace the counter device control board. • Replace the backup battery.