Các lỗi thường gặp

Code :
  • Code: 161-002
  • Description: IPU error
    The machine detects an error during an access to the Ri.
  • Causes: • Defective BICU board
  • Remedy: Replace the BICU board.
  • Code: 161-003
  • Description: IPU error
    The IPU fails to configure or initialize the DRAM.
  • Causes: • Defective BICU board
  • Remedy: Replace the BICU board.
  • Code: 165
  • Description: Copy data security unit error B829
    The copy data security option is installed by not operating correctly.
  • Causes: • Copy data security card corrupted • The board is not installed or the board is defective
  • Remedy:
  • Code: 181
  • Description: Inverter Fan Error
    When the exposure lamp is triggered on, the inverter fan motor does not rotate.
  • Causes: • SIOB defective • BCU defective • Inverter fan motor defective • Harness between the inverter fan motor - SIOB is disconnected • Harness between the SIOB – BCU is disconnected • Harness between the SIOB – PSU is disconnected
  • Remedy:
  • Code: 182
  • Description: Scanner Fan Error: Right Side
    The fan located on the right side of the exposure unit is not rotating.
  • Causes: • Check the fan connections • Fan defective • Check SBU connection • SBU defective
  • Remedy:
  • Code: 185
  • Description: CIS transmission error
    Error caused during ASIC register's automatic initialization on the CIS, or during transmission between the CIS – DF.
  • Causes: • Harness between the CIS – DF is disconnected • CIS defective
  • Remedy:
  • Code: 186
  • Description: CIS LED error
    LED on the CIS causes error • During initializing, the ration of the average between leading-edge area and rearedge is beyond the permissible level (0.7 – 1.43). • During scanning, the shading data peak is under 32(8bit).
  • Causes: • Harness CN210 and CN220 on ADF are disconnected. • Otherwise, replace CIS.
  • Remedy:
  • Code: 187
  • Description: CIS BK level error
    The BK level scanned by CIS is abnormal. The BK level average of R, G or B is/are not from 2 to 62. 0 < Calibrated BK data level < 255(10bit).
  • Causes: • Turn off the machine. • Make sure CN210 and CN220 are connected firmly. • Turn on the machine.
  • Remedy: