Description: Laser Synchronization Detector Error: K Leading Edge (Not LD0) While the polygon motor is rotating normally, no synchronizing detection signal is output for black, leading edge for any LD other than LD0.
Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
Remedy:
Code: 230
Description: FGATE ON error: K The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [K].
Causes: • Defective ASIC • Poor connection between controller and BICU. • Defective BICU
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.
Code: 231
Description: FGATE OFF error: K • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K]. • The PFGATE ON signal still asserts when the next job starts.
Causes:
Remedy: 1. Check the connection between the controller board and the BICU. 2. Replace the BICU. 3. Replace the controller board.
Code: 240
Description: LD error: K The BICU detects LDB error a few times consecutively when LDB unit turns on after LDB initialization.
Causes: • Worn-out LD • Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the BICU.
Code: 300
Description: Charge corona output error The feedback voltage from the charge corona unit is detected too high 9 times.
Causes: • Charge corona power pack defective • Charge corona harness disconnected • Poor charge corona unit connection
Remedy:
Code: 303
Description: Charge corona grid leak When the high voltage is output to the corona grid, feedback voltage exceeds the prescribed value 9 times.
Causes: • Charge corona power pack defective • Charge corona harness disconnected • Poor charge corona unit connection
Remedy:
Code: 304
Description: Charge grid circuit open When high voltage goes to the corona grid, feedback voltage is more than the set value 9 times. This feedback voltage is used to update PWM for output control.
Causes: • Charge corona unit defective or disconnected • Charge corona harness defective • Charge corona power pack is defective.
Remedy:
Code: 305
Description: Charge corona wire cleaner error 1 The charge cleaner pad does not arrive at the home position: Motor locked within 4 s after switching on, or does not lock within 30 s. Motor locked within 10 s after reversing, or does not lock within 30 s.
Causes: • Charge corona wire cleaner motor defective • Motor driver defective