Description: BICU, LCT communication/timeout error After 1 data frame is sent to the LCT, an ACK signal is not received within 100 ms, and is not received after 3 retries.
Causes: • Serial line connection unstable • External noise on the line
Remedy:
Code: 627
Description: BICU, LCT communication/break reception error During communication with the LCT, the BICU received a break (Low) signal.
Causes: • Serial line connection unstable • External noise on the line
Remedy:
Code: 628
Description: Fan folder communication error 1 The main machine issued a timeout three failed attempts to communicate with the fan folder unit. Possible causes: • There was no answer from the fan folder within 100 ms in response to data sent from the main machine. • The fan folder unit was switched off while folding was in progress. • The main machine received an illegal command from the fan folder. • 60 sec. after the main machine fed the document to the fan folder, the fan folder failed to notify the main machine that the folded document has exited the fan folder.
Causes: • Fan folder not connected to main machine • Fan folder main control unit connector loose, broken, defective • Fan folder main control unit defective
Remedy:
Code: 629
Description: Fan folder communication error 2: Cross Folder There was no answer from the fan folder within 100 ms in response to data sent from the main machine.
Causes: • Fan folder not connected to main machine • Fan folder main control unit connector loose, broken, defective • Fan folder main control unit defective