Các lỗi thường gặp

Code :
  • Code: 530-00
  • Description: Main fan error The main fan motor lock signal goes high for 5 s while the fan is on.
  • Causes: • Fan motor overloaded due to obstruction • Fan connector disconnected
  • Code: 540-01
  • Description: Fusing exit motor error The PLL lock signal was low for 2 s during motor operation.
  • Causes: • Motor lock caused by physical overload • Motor drive PCB defective
  • Code: 540-02
  • Description: Fusing web motor error 1 The amount of current detected during operation of the web motor exceeded 350 mA in 5 successive samples.
  • Causes: • Motor connection loose, broken, defective • Motor disconnected • Motor lock or short
  • Code: 540-03
  • Description: Fusing web motor error 2 SC540-02 has occurred three times and the machine has shut down automatically due to failure of the web motor.
  • Causes: • Web motor harness loose, broken, defective • Web motor disconnected • Web motor defective
  • Code: 540-04
  • Description: Fusing web motor error 3 SC540-02 has occurred at total of 10 times and the machine has shut down automatically due to failure of the web motor.
  • Causes: • Web motor harness loose, broken, defective • Web motor disconnected • Web motor defective
  • Code: 541
  • Description: Fusing thermistor open The fusing temperature detected by the center thermistor was below 0°C for 7 s.
  • Causes: • Thermistor open • Thermistor connector defective • Thermistor damaged, or out of position • Fusing temperature –15% less than the standard input voltage
  • Code: 542-001
  • Description: Fusing temperature warm-up error 1: Center themistor The center thermistor that touches the hot roller determined that the hot roller failed to reach the warm-up temperature within the prescribed time.
  • Causes: • Fusing lamp disconnected • Thermistor warped, out of position • Thermostat has opened
  • Code: 542-002
  • Description: Fusing temperature warm-up error 2: Center themistor The center thermistor that touches the hot roller determined that the hot roller failed to reach 100 within the prescribed time.
  • Causes: • Fusing lamp disconnected • Thermistor warped, out of position • Thermostat has opened
‹ First  < 6 7 8 9 10 11 12 >  Last ›