Description: ID sensor adjustment error: Timeout error Vsg falls out of the adjustment target (4.0 ±0.2V) during Vsg checking within 20 sec.
Causes: • ID sensor defective • ID sensor harness disconnected • ID sensor connector defective • IOB defective • ID sensor pattern not written correctly • Incorrect image density • Charge power pack defective • ID sensor dirty
Code: 375-00
Description: ID sensor error: Drum surface voltage error The ID sensor output voltage is 5.0V and the PWM signal input to the ID sensor is 0 when checking the ID sensor pattern.
Causes: • ID sensor defective • ID sensor harness disconnected • ID sensor connector defective • IOB defective • ID sensor pattern not written correctly • Incorrect image density • Charge power pack defective • ID sensor dirty
Code: 376-00
Description: ID sensor error: Pattern edge detection failed For 2 s during the ID sensor pattern check, the ID sensor pattern edge voltage is not 2.5V or the pattern edge is not detected within 800 ms.
Causes: • ID sensor defective • ID sensor harness disconnected • ID sensor connector defective • IOB defective • ID sensor pattern not written correctly • Incorrect image density • Charge power pack defective • ID sensor dirty
Code: 377-00
Description: ID sensor error: Potential surface reading error The Vp value, which measures the reflectivity of the ID sensor pattern, was not in the range of -70V to -400V.
Description: ID sensor pattern error One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern. • Vsp greater than or equals 2.5V • Vsg less than 2.5 • Vsp = 0V • Vsg = 0
Causes: • ID sensor defective • ID sensor harness disconnected • ID sensor connector defective • IOB defective • ID sensor pattern not written correctly • Incorrect image density • Charge power pack defective • ID sensor dirty
Code: 380-01
Description: Potential sensor calibration error (VM100) During drum potential sensor calibration, when -100V is applied to the drum, the output value is out of the prescribed range.
Causes: • Potential sensor defective • Potential sensor harness disconnected • Potential sensor connector defective or disconnected • IOB defective • OPC connector defective • Development power pack defective
Code: 380-11
Description: Potential sensor calibration error (VM800) During drum potential sensor calibration, when -800V is applied to the drum, the output value is out of the prescribed range.
Causes: • Potential sensor defective • Potential sensor harness disconnected • Potential sensor connector defective or disconnected • IOB defective • OPC connector defective • Development power pack defective
Code: 380-21
Description: Potential sensor calibration error (skew) During drum potential sensor calibration, the drum potential sensor output voltage does not meet specification when test voltages (–100V, –800V) are applied to the drum.
Causes: • Potential sensor defective • Potential sensor harness disconnected • Potential sensor connector defective or disconnected • IOB defective • OPC connector defective • Development power pack defective