Code: SC531-01

Description: Development Intake Fan/Right Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan

Code: SC531-02

Description: Development Intake Fan/Left Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan

Code: SC531-03

Description: Drive Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan

Code: SC533-01

Description: PSU Exhaust Heat Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan

Code: SC533-03

Description: PSU Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan

Code: SC533-04

Description: Controller Box Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan

Code: SC534-01

Description: Main Exhaust Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan

Code: SC534-02

Description: Toner Supply Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan