Description: Fusing exit sensor fan error The BICU does not receive the lock signal 10 seconds after turning on the fusing fan motor.
Causes: Defective fusing fan motor
Remedy: 1. Replace the fusing exit sensor fan motor (at the front right side of the machine).
Code: 535
Description: PSU fan 1/2 error The BICU does not receive the lock signal 10 seconds after turning on the PSU fan 1/2 motor.
Causes: Defective PSU fan motor 1/2
Remedy: 1. Replace the PSU fan motor 1/2
Code: 536
Description: Controller fan error The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
Causes: Defective controller fan motor
Remedy: 1. Replace the controller fan motor.
Code: 540
Description: Fusing/Paper exit motor error The BICU does not receive the lock signal 10 seconds after turning on the Fusing/Paper exit motor.
Causes: Motor overload. Defective fusing/paper exit motor
Remedy: 1. Replace the fusing/paper exit motor.
Code: 541
Description: Heating roller thermistor error 1 The temperature measured by the heating roller thermistor does not reach 0°C for 6 seconds.
Causes: Loose connection of the heating roller thermistor. Defective heating roller thermistor. Defective thermopiler disc.
Remedy: 1. Check if the heating roller thermistor is firmly connected. 2. Replace the heating roller thermistor. 3. Replace the thermopile.
Code: 542
Description: Heating roller warm-up error 1 After the main switch is turned on or the cover is closed, the increment of the heating roller temperature per 10 seconds is 30°C or less. If this condition is detected five times consecutively, SC 542 is defined. The heating roller temperature does not reach 100°C for 15 seconds after the heating lamp on. The heating roller temperature does not reach the ready temperature while 60 seconds after the heating lamp on. The center temperature of the heating roller does not reach the ready temperature for 30 seconds after the both edge temperature of the heating roller has reached the ready temperature.
Remedy: 1. Check if the heating roller thermistor is firmly connected. 2. Replace the thermistor. 3. Check or replace the thermopile. 4. Replace the heating roller lamp.
Code: 543
Description: Heating roller fusing lamp overheat 1 (software error) The detected fusing temperature stays at 230°C for 1 second.
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.
Code: 544
Description: Heating roller fusing lamp overheat 1 (hardware error) During stand-by mode or a print job, the detected heating roller temperature reaches 250 °C.