Description: Pressure roller thermister error 3 The temperature measured by the pressure roller thermistor (center) does not reach 0 °C for 20 seconds.
Remedy: 1. Check that the pressure roller thermistor (center)is firmly connected. 2. Replace the pressure roller thermistor (center).
Code: 563
Description: Pressure roller overheat 3 (software error) The detected fusing roller temperature stays at 230°C or more for 1 second.
Causes: • Defective PSU • Defective BCU
Remedy: 1. Replace the pressure roller thermistor (center). 2. Replace the PSU. 3. Replace the BCU.
Code: 564
Description: Pressure roller overheat 3 (hardware error) The pressure roller thermistor (center) detects 250°C or more.
Causes: • Defective PSU • Defective BCU • Defective pressure roller thermistor (center) • Defective fusing control system
Remedy: 1. Replace the pressure roller thermistor (center). 2. Replace the PSU. 3. Replace the BCU.
Code: 565
Description: Pressure roller fusing lamp consecutive full power 3 When the fusing unit is not running in the ready condition, the pressure roller fusing lamp keeps ON full power for 250 seconds or more.amp on.
Remedy: 1. Replace the pressure roller fusing lamp. 2. Replace the pressure roller thermostat. 3. Replace the PSU.
Code: 571
Description: Pressure roller thermister error 4 The temperature measured by the pressure roller thermistor (end) does not reach 0 °C for 20 seconds.amp on.
Causes: • Loose connection of pressure roller thermistor (end) • Defective pressure roller thermistor (end)r more.
Remedy: 1. Check that the pressure roller thermistor (end) is firmly connected. 2. Replace the pressure roller thermistor (end).
Code: 573
Description: Pressure roller overheat 4 (software error) The detected pressure roller temperature stays at 230°C or more for 1 second.
Remedy: 1. Replace the pressure roller thermistor (end). 2. Replace the PSU. 3. Replace the BCU.
Code: 610
Description: Mechanical counter error: K This SC is only for NA models. The machine detects the mechanical counter error when SP5987-001 is set to "1".