Description: Charge P.P. output error: Cy The feedback voltage of the charge AC for each color is 0.3 V or less for 0.2 seconds after the charge AC has turned on.
Causes: Disconnected or broken harnesses of the HVPS. Defective PCDU. Defective HVPS.
Remedy: 1. Check or replace the harnesses of the HVPS. 2. Reinstall or replace the PCDU. 3. Replace the HVPS.
Description: Charge P.P. output error: Ma The feedback voltage of the charge AC for each color is 0.3 V or less for 0.2 seconds after the charge AC has turned on.
Causes: Disconnected or broken harnesses of the HVPS. Defective PCDU. Defective HVPS.
Remedy: 1. Check or replace the harnesses of the HVPS. 2. Reinstall or replace the PCDU. 3. Replace the HVPS.
Description: Charge P.P. output error: Ye The feedback voltage of the charge AC for each color is 0.3 V or less for 0.2 seconds after the charge AC has turned on.
Causes: Disconnected or broken harnesses of the HVPS. Defective PCDU. Defective HVPS.
Remedy: 1. Check or replace the harnesses of the HVPS. 2. Reinstall or replace the PCDU. 3. Replace the HVPS.
Description: Color development motor error The motor LOCK signal is not detected for more than two seconds while the motor START signal is on.
Causes: Color development motor slip due to an increase in the torque caused by connected components. Defective motor
Remedy: 1. Adjust the torque properly by replacing or cleaning the PCDU. 2. Replace the PCDU. 3. Replace the development motor: CMY if load torque is normal.
Description: TD sensor (Vt high) error 1: Bk The Vt value of the black TD sensor exceeds the specified value (SP3030-031)+-0.2 V for three consecutive times.
Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCDU for damage. 2. Check the drawer connector. 3. Replace the defective PCDU.
Description: TD sensor (Vt high) error 1: Cy The Vt value of the cyan TD sensor exceeds the specified value (SP3030-032)+-0.2 V for three consecutive times.
Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCDU for damage. 2. Check the drawer connector. 3. Replace the defective PCDU.
Description: TD sensor (Vt high) error 1: Ma The Vt value of the magenta TD sensor exceeds the specified value (SP3030-033)+-0.2 V for three consecutive times.
Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and PCDU for damage. 2. Check the drawer connector. 3. Replace the defective PCDU.
Description: TD sensor (Vt high) error 1: Ye The Vt value of the yellow TD sensor exceeds the specified value (SP3030-034)+-0.2 V for three consecutive times.
Causes: Black, magenta, cyan, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.