Description: TD sensor (Vt) upper limit error: Bk The Vt value upper limit of the black TD sensor (SP3210-001) exceeds the specified value (SP3211-002) for the specified number of times (SP3211-003) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Code: 361-02
Description: TD sensor (Vt) upper limit error 1: Cy The Vt value upper limit of the cyan TD sensor (SP3210-002) exceeds the specified value (SP3211-002) for the specified number of times (SP3211-003) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Code: 361-03
Description: TD sensor (Vt) upper limit error 1: Ma The Vt value upper limit of the magenta TD sensor (SP3210-003) exceeds the specified value (SP3211-002) for the specified number of times (SP3211-003) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Code: 361-04
Description: TD sensor (Vt) upper limit error 1: Ye The Vt value upper limit of the yellow TD sensor (SP3210-004) exceeds the specified value (SP3211-002) for the specified number of times (SP3211-003) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Code: 362-01
Description: TD sensor (Vt) lower limit error: Bk The Vt value lower limit of the black TD sensor (SP3210-001) falls below the specified value (SP3211-004) for the specified number of times (SP3211-005) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Code: 362-02
Description: TD sensor (Vt) lower limit error 1: Cy The Vt value lower limit of the cyan TD sensor (SP3210-002) falls below the specified value (SP3211-004) for the specified number of times (SP3211-005) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Code: 362-03
Description: TD sensor (Vt) lower limit error 1: Ma The Vt value lower limit of the magenta TD sensor (SP3210-003) falls below the specified value (SP3211-004) for the specified number of times (SP3211-005) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Code: 362-04
Description: TD sensor (Vt) lower limit error 1: Ye The Vt value lower limit of the yellow TD sensor (SP3210-004) falls below the specified value (SP3211-004) for the specified number of times (SP3211-005) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.