Description: Copy Data Security Unit error The copy data security board is not detected or a device check error occurs when the copy data security function is set "ON" with the initial setting.
Causes: Incorrect installation of the copy data security board. Defective copy data security board
Remedy: 1. Reinstall the copy data security board. 2. Replace the copy data security board.
Code: 195
Description: Serial Number Mismatch Serial number stored in the memory does not have the correct code.
Causes: EEPROM defective. BICU replaced without original EEPROM
Remedy: 1. Check the serial number with SP5-811-002. 2. If the stored serial number is incorrect, contact your supervisor.
Code: 202-01
Description: Polygon motor error 1: ON timeout: Bk, Cy The polygon mirror motor does not reach the targeted operating speed within the specified time after turning on or changing speed
Causes: Defective or disconnected harness to polygon motor driver board. Defective polygon motor driver board. Defective polygon motor
Remedy: 1. Replace the polygon motor. 2. Replace the laser optics housing unit. 3. Replace the harness. 4. Replace the BICU.
Code: 202-03
Description: Polygon motor error 1: ON timeout: Ma, Ye The polygon mirror motor does not reach the targeted operating speed within the specified time after turning on or changing speed
Causes: Defective or disconnected harness to polygon motor driver board. Defective polygon motor driver board. Defective polygon motor
Remedy: 1. Replace the polygon motor. 2. Replace the laser optics housing unit. 3. Replace the harness. 4. Replace the BICU.
Code: 202-03
Description: Polygon motor error 2: OFF timeout: Ma, Ye The polygon mirror motor does not leave the READY status within the given time after the polygon motor switches off.
Causes: Disconnected or defective harness to polygon motor driver board. Defective polygon motor driver board. Defective polygon motor
Remedy: 1. Check or replace the harness. 2. Replace the polygon motor.
Code: 203-01
Description: Polygon motor error 2: OFF timeout: Bk, Cy The polygon mirror motor does not leave the READY status within the given time after the polygon motor switches off.
Causes: Disconnected or defective harness to polygon motor driver board. Defective polygon motor driver board. Defective polygon motor
Remedy: 1. Check or replace the harness. 2. Replace the polygon motor.
Code: 204-01
Description: Polygon motor error 0: XSCRDY signal error: Bk, Cy The SCRDY_N signal goes HIGH (inactive) during a writing operation.
Causes: Disconnected or defective harness to polygon motor driver board. Defective polygon motor. Defective polygon motor driver board
Remedy: 1. Check or replace the harness. 2. Replace the polygon motor. 3. Replace the BICU.
Code: 204-03
Description: Polygon motor error 1: XSCRDY signal error: Ma, Ye The SCRDY_N signal goes HIGH (inactive) during a writing operation.
Causes: Disconnected or defective harness to polygon motor driver board. Defective polygon motor. Defective polygon motor driver board
Remedy: 1. Check or replace the harness. 2. Replace the polygon motor. 3. Replace the BICU.