Description: Shutter overrun error 1: Close The shutter close sensor loses the "ON" signal after the shutter was closed.
Causes: • Defective motor • Change of load to shutter motor
Remedy: Replace the shutter on the laser optics housing unit.
Code: 292
Description: Shutter overrun error 2: Close The shutter close sensor detects "ON" after SC 291 has occurred.
Causes: • Defective motor • Change of load to shutter motor
Remedy: Replace the shutter on the laser optics housing unit.
Code: 293
Description: Shutter sensor time over error: Open The shutter open sensor does not detect "ON" for 2000 msec after the shutter motor turns on.
Causes: • Defective shutter close sensor • Disconnected or broken harness • Defective shutter motor • Defective shutter • Shutter motor overload • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the shutter on the laser optics housing unit. 3. Replace the shutter motor. 4. Replace the shutter close sensor. 5. Replace the IOB.
Code: 294
Description: Shutter overrun error 1: Open The shutter open sensor loses the "ON" signal after the shutter was closed.
Causes: • Defective motor • Change of load to shutter motor
Remedy: 1. Replace the shutter on the laser optics housing unit.
Code: 295
Description: Shutter overrun error 2: Open The shutter open sensor detects "ON" after SC 291 has occurred.
Causes: • Defective motor • Change of load to shutter motor
Remedy: 1. Replace the shutter on the laser optics housing unit.
Code: 296
Description: Shutter open/close sensor error Both shutter open sensor and close sensor detect "ON" at the same time.
Causes: • Broken harness(es) of the shutter open/close sensors
Remedy: Replace the shutter on the laser optics housing unit.
Code: 300
Description: AC charge output error [K] The measured voltage is not proper when IOB measures the charge output for each color.
Causes: • Disconnected or broken high voltage cable • Defective or not installed PCU • Defective high voltage power supply
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected colour. 3. Replace the high voltage power supply.
Code: 301
Description: AC charge output error [M] The measured voltage is not proper when IOB measures the charge output for each color.
Causes: • Disconnected or broken high voltage cable • Defective or not installed PCU • Defective high voltage power supply
Remedy: 1. Check or replace the connectors. 2. Replace the PCU for the affected colour. 3. Replace the high voltage power supply.