Các lỗi thường gặp

Code :
  • Code: 563
  • Description: Heating roller overheat 3 (software error)
    The detected fusing roller temperature stays at 230°C or more for 1 second.
  • Causes: • Defective PSU • Defective IOB • Defective BICU
  • Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.
  • Code: 564
  • Description: Heating roller overheat 3 (hardware error)
    The thermopile detects 250°C or more.
  • Causes: • Defective PSU • Defective IOB • Defective BICU • Defective fusing control system
  • Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.
  • Code: 565
  • Description: Heating lamp consecutive full power 3
    When the fusing unit is not running in the ready condition, the pressure roller-fusing lamp keeps ON full power for 120 seconds or more.
  • Causes: • Broken heating roller fusing lamp
  • Remedy: 1. Replace the pressure roller lamp. 2. Replace the PSU.
  • Code: 569
  • Description: Pressure roller contact sensor error
    Pressure roller contact sensor failed to detect 3 times.
  • Causes: • Broken or defective pressure roller contact sensor • Deformed or broken pressure roller contact sensor feeler • Defective fusing unit
  • Remedy: 1. Turn the main power switch ON/OFF.
  • Code: 581
  • Description: IH inverter input voltage error
    The IH inverter detects 70V or less/140V or more for 10 seconds.
  • Causes: • Unusual input voltage • Disconnected CN981 on the IH inverter • Defective IH inverter
  • Remedy: 1. Check CN981 on the IH inverter. 2. Replace the IH inverter.
  • Code: 582
  • Description: IH inverter current error at power on
    The output current from the IH inverter does not reach the proper value when the IH inverter turns on.
  • Causes: • Disconnected power input terminal 1 and 2 • Defective IH inverter • Defective IH coil unit • Defective fusing unit
  • Remedy: 1. Check the power input terminals 1 and 2. 2. Replace the IH inverter. 3. Replace the IH coil unit. 4. Replace the fusing unit.
  • Code: 585
  • Description: IH coil unit full power (1250W) error
    The IH coil unit full power (1250W) continues for 220 seconds or more.
  • Causes: • Defective IH inverter • Defective BICU • Defective IOB • Broken connection between IH inverter and IOB • Defective thermopile
  • Remedy: 1. Replace the IH inverter. 2. Replace the BICU. 3. Replace the IOB. 4. Check the connection between IH inverter and IOB. 5. Replace the thermopile.
  • Code: 610
  • Description: Mechanical counter error: K
    This SC is only for NA models. The machine detects the mechanical counter error when SP5987-001 is set to "1".
  • Causes: • Disconnected mechanical counter • Defective mechanical counter
  • Remedy: 1. Check or replace the mechanical counter.