Description: Counter device error 4 A backup battery error was returned by the counter device.
Causes: • Counter device control board defective • Backup battery of counter device defective
Remedy:
Code: 636
Description: SD Card Error
Causes: 01 - Expanded authentication module error There is no expanded authentication module in the machine. The SD card or the file of the expanded authentication module is broken. There is no DESS module in the machine. • No expanded authentication module • Defective SD card • No DESS module 1. Install the expanded authentication module. 2. Install the SD card. 3. Install the DESS module. 02 - Version error The version of the expanded authentication module is not correct. • Incorrect module version 1. Install the correct file of the expanded authentication module.
Remedy:
Code: 641
Description: BICU control data transfer abnormal A sampling of the control data sent from the BICU reveals an abnormality.
Description: Communication error of the remote service modem (Cumin-M)
Causes: -001 - Authentication error The authentication for the Cumin-M fails at a dial up connection. • Incorrect SP settings • Disconnected telephone line • Disconnected modem board 1. Check and set the correct user name (SP5816-156) and password (SP5816-157). -004 - Incorrect modem setting Dial up fails due to the incorrect modem setting. Same as -001 1. Check and set the correct AT command (SP5819-160). -005 - Communication line error The supplied voltage is not sufficient due to the defective communication line or defective connection. Same as -001 1. Consult with the user's local telephone company.
Remedy:
Code: 651
Description: Incorrect dial up connection -001: Program parameter error -002: Program execution error An unexpected error occurs when the modem (Cumin-M) tries to call the center with a dial up connection.
Causes: • Caused by a software bug
Remedy: No action required because this SC does not interfere with operation of the machine.
Code: 669
Description: EEPROM error Retry of EEPROM communication fails three times after the machine has detected the EEPROM error.
Causes: • Caused by noise
Remedy: Turn the main power switch off and on.
Code: 670
Description: Engine start up error The ready signal from the engine board is not detected.