Description: Mechanical counter error: FC This SC is only for NA models. The machine detects the mechanical counter error when SP5987-001 is set to "1".
Remedy: 1. Check the cable connection of the ARDF. 2. Shut out the external noise. 3. Replace the ARDF. 4. Replace the BICU board.
Code: 621
Description: Finisher communication error While the IOB communicates with an optional unit, an SC code is displayed if one of following conditions occurs. • The IOB receives the break signal which is generated by the peripherals only just after the main switch is turned on. • When the IOB does not receive an OK signal from a peripheral 100ms after sending a command to it. The IOB resends the command. The IOB does not receive an OK signal after sending the command 3 times.
Causes: • Cable problems • IOB problems • BICU problems • PSU problems in the machine • Main board problems in the peripherals
Remedy: 1. Check if the cables of peripherals are correctly connected. 2. Replace the IOB or main board of peripherals. 3. Replace the BICU if no power is supplied to peripherals.
Code: 622
Description: Paper tray unit communication error While the IOB communicates with an optional unit, an SC code is displayed if one of following conditions occurs. • The IOB receives the break signal which is generated by the peripherals only just after the main switch is turned on. • When the IOB does not receive an OK signal from a peripheral 100ms after sending a command to it. The IOB resends the command. The IOB does not receive an OK signal after sending the command 3 times.
Causes: • Cable problems • IOB problems • BICU problems • PSU problems in the machine • Main board problems in the peripherals
Remedy: 1. Check if the cables of peripherals are correctly connected. 2. Replace the IOB or main board of peripherals. 3. Replace the BICU if no power is supplied to peripherals.
Code: 623
Description: 2nd Paper Bank communication error This SC is not issued for this machine. When a communication error signal between the 1st paper bank and 2nd paper bank is received.
Causes: • Loose connector
Remedy:
Code: 632
Description: Counter device error 1 After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device.
Remedy:
Code: 633
Description: Counter device error 2 After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device.
Remedy:
Code: 634
Description: Counter device error 3 A backup RAM error was returned by the counter device.
Causes: • Counter device control board defective • Backup battery of counter device defective