Causes: • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K]. • The PFGATE ON signal still asserts when the next job starts.
Remedy: • Check the connection between the controller board and the IPU. • Replace the IPU.
Causes: • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [C]. • The PFGATE ON signal still asserts when the next job starts.
Remedy: • Check the connection between the controller board and the IPU. • Replace the IPU.
Causes: • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [M]. • The PFGATE ON signal still asserts when the next job starts.
Remedy: • Check the connection between the controller board and the IPU. • Replace the IPU.
Causes: • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [Y]. • The PFGATE ON signal still asserts when the next job starts.
Remedy: • Check the connection between the controller board and the IPU. • Replace the IPU.