Các lỗi thường gặp

Code :
  • Code: 202
  • Description: Polygon motor error 1: ON timeout
    The polygon mirror motor does not reach the targeted operating speed within the specified time after turning on or changing speed
  • Causes: • Defective or disconnected harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor.
  • Remedy: 1. Replace the polygon motor. 2. Replace the laser optics housing unit. 3. Replace the harness. 4. Replace the BICU.
  • Code: 203
  • Description: Polygon motor error 2: OFF timeout
    The polygon mirror motor does leave the READY status within 3 seconds after the polygon motor switches off.
  • Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor
  • Remedy: 1. Check or replace the harness. 2. Replace the polygon motor.
  • Code: 204
  • Description: Polygon motor error 3: XSCRDY signal error
    The SCRDY_N signal goes HIGH (inactive) while the laser diode is firing.
  • Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor • Defective polygon motor driver board
  • Remedy: 1. Check or replace the harness. 2. Replace the polygon motor.
  • Code: 210
  • Description: Laser synchronizing detection error: end position [K]
    The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification
  • Causes: Disconnected or defective harness to synchronizing detector for end position. Defective synchronizing detector board. Defective LD board or driver. Defective BICU.
  • Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the BICU.
  • Code: 211
  • Description: Laser synchronizing detection error: end position [Y]
    The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification
  • Causes: Disconnected or defective harness to synchronizing detector for end position. Defective synchronizing detector board. Defective LD board or driver. Defective BICU.
  • Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the BICU.
  • Code: 212
  • Description: Laser synchronizing detection error: end position [M]
    The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification
  • Causes: Disconnected or defective harness to synchronizing detector for end position. Defective synchronizing detector board. Defective LD board or driver. Defective BICU.
  • Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the BICU.
  • Code: 213
  • Description: Laser synchronizing detection error: end position [C]
    The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification
  • Causes: Disconnected or defective harness to synchronizing detector for end position. Defective synchronizing detector board. Defective LD board or driver. Defective BICU.
  • Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the BICU.
  • Code: 220
  • Description: Laser synchronizing detection error: start position [K]: LD0
    The laser synchronizing detection signal for the start position of the LDB [K], [Y], [M], [C] is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
  • Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective IPU
  • Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the BICU.