Description: TD sensor adjustment error: K During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
Causes: Heat seal not removed from a new developer pack. TD harness sensor disconnected, loose or defective. TD sensor defective. Harness between TD sensor and drawer disconnected, defective.
Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the defective PCDU.
Code: 373
Description: TD sensor adjustment error: M During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
Causes: Heat seal not removed from a new developer pack. TD harness sensor disconnected, loose or defective. TD sensor defective. Harness between TD sensor and drawer disconnected, defective.
Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the defective PCDU.
Code: 374
Description: TD sensor adjustment error: C During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
Causes: Heat seal not removed from a new developer pack. TD harness sensor disconnected, loose or defective. TD sensor defective. Harness between TD sensor and drawer disconnected, defective.
Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the defective PCDU.
Code: 375
Description: TD sensor adjustment error: Y During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.7V) +- 0.2V
Causes: Heat seal not removed from a new developer pack. TD harness sensor disconnected, loose or defective. TD sensor defective. Harness between TD sensor and drawer disconnected, defective.
Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the defective PCDU.
Code: 380
Description: Drum gear position sensor error: K The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
Causes: • Dirty or defective drum gear position sensor
Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCDU.
Code: 381
Description: Drum gear position sensor error: M The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
Causes: • Dirty or defective drum gear position sensor
Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCDU.
Code: 382
Description: Drum gear position sensor error: C The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
Causes: • Dirty or defective drum gear position sensor
Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCDU.
Code: 383
Description: Drum gear position sensor error: Y The machine does not detect the drum position signal for 3 seconds at the drum phase adjustment.
Causes: • Dirty or defective drum gear position sensor
Remedy: 1. Clean the drum gear position sensor. 2. Check the harness connection. 3. Replace the drum gear position sensor. 4. Replace the PCDU.