Description: Heating lamp consecutive full power 3 When the fusing unit is not running in the ready condition, the pressure roller-fusing lamp keeps ON full power for 120 seconds or more.
Causes: • Broken heating roller fusing lamp
Remedy: 1. Replace the pressure roller lamp. 2. Replace the PSU.
Description: IH inverter current error at power on The output current from the IH inverter does not reach the proper value when the IH inverter turns on.
Causes: • Disconnected power input terminal 1 and 2 • Defective IH inverter • Defective IH coil unit • Defective fusing unit
Remedy: 1. Check the power input terminals 1 and 2. 2. Replace the IH inverter. 3. Replace the IH coil unit. 4. Replace the fusing unit.
Description: IH coil unit full power (1250W) error The IH coil unit full power (1250W) continues for 220 seconds or more.
Causes: • Defective IH inverter • Defective BICU • Defective IOB • Broken connection between IH inverter and IOB • Defective thermopile
Remedy: 1. Replace the IH inverter. 2. Replace the BICU. 3. Replace the IOB. 4. Check the connection between IH inverter and IOB. 5. Replace the thermopile.
Description: Mechanical counter error: K This SC is only for NA models. The machine detects the mechanical counter error when SP5987-001 is set to "1".