Code: 541

Description: Heating roller thermopile error
The temperature measured by the heating roller thermopile does not reach 0°C for 6 seconds.
Causes: • Loose connection of the heating roller thermopile • Defective heating roller thermopile • Defective thermopile
Remedy: 1. Check if the heating roller thermopile is firmly connected. 2. Replace the heating roller thermopile.

Code: 542

Description: Heating roller warm-up error 1
• After the main switch is turned on or the cover is closed, the increment of the heating roller temperature per 10 seconds is 30°C or less. If this condition is detected five times consecutively, SC 542 is defined. • The heating roller temperature does not reach 100°C for 15 seconds after the heating lamp on. • The heating roller temperature does not reach the ready temperature while 60 seconds after the heating lamp on. • The center temperature of the heating roller does not reach the ready temperature for 30 seconds after the both edge temperature of the heating roller has reached the ready temperature.
Causes: • Dirty or defective thermopile • Defective thermistor • Defective heating roller lamp
Remedy: 1. Check if the heating roller thermopile is firmly connected. 2. Replace the thermopile. 3. Replace the IH coil unit.

Code: 543

Description: Heating roller fusing lamp overheat 1 (software error)
The detected fusing temperature stays at 230°C for 1 second.
Causes: • Defective PSU • Defective IOB • Defective BICU
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.

Code: 544

Description: Heating roller fusing lamp overheat 1 (hardware error)
During stand-by mode or a print job, the detected heating roller temperature reaches 250 °C.
Causes: • Defective PSU • Defective IOB • Defective BICU • Defective fusing control system
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.

Code: 545

Description: Heating roller fusing lamp consecutive full power 1
When the fusing unit is not running in the ready condition, the heating roller fusing lamp keeps on full power for 8 seconds.
Causes: • Broken heating roller thermistor
Remedy: 1. Check the power supply source. 2. Replace the +24V fuse on the PSU. 3. Replace the PSU

Code: 547

Description: Zero cross error
• The zero cross signal is detected three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 2 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
Causes: • Defective fusing lamp relay • Defective fusing lamp relay circuit • Unstable power supply
Remedy: 1. Check the power supply source. 2. Replace the +24V fuse on the PSU. 3. Replace the PSU

Code: 548

Description: Fusing unit rotation error The fusing belt sensor does not detect change in the actuator for 0.5 seconds after the fusing/paper exit motor has turned on.
Causes: • Defective fusing/paper exit motor • Deformed actuator for the fusing belt sensor • Defective fusing belt sensor • Broken connection between IH inverter and IOB • Incorrectly set fusing unit
Remedy: 1. Check if the fusing unit is correctly set. 2. Check or replace the actuator for fusing belt sensor. 3. Replace the fusing belt sensor. 4. Replace the IH inverter. 5. Check the connection between IH inverter and IOB.

Code: 548

Description: Fusing unit rotation error
The fusing belt sensor does not detect change in the actuator for 0.5 seconds after the fusing/paper exit motor has turned on.
Causes: • Defective fusing/paper exit motor • Deformed actuator for the fusing belt sensor • Defective fusing belt sensor • Broken connection between IH inverter and IOB • Incorrectly set fusing unit
Remedy: 1. Check if the fusing unit is correctly set. 2. Check or replace the actuator for fusing belt sensor. 3. Replace the fusing belt sensor. 4. Replace the IH inverter. 5. Check the connection between IH inverter and IOB.