Code: 442

Description: Image transfer belt contact motor error
The image transfer belt contact sensor does not detect the movement of actuator at the sensor while the polygon motor rotates.
Causes: • Dirty image transfer belt contact sensor • Defective image transfer belt contact motor • Disconnected connector of image transfer belt contact sensor or motor • Disconnected cable
Remedy: 1. Replace the image transfer belt contact sensor. 2. Replace the image transfer belt contact motor.

Code: 443

Description: Image transfer unit error
The machine detects the encoder sensor error.
Causes: • Defective encoder sensor • Image transfer unit installation error • Defective image transfer unit motor
Remedy: 1. Check if the image transfer unit is correctly set. 2. Replace the image transfer unit motor. 3. Replace the image transfer unit.

Code: 452

Description: Paper transfer unit contact error
The paper transfer unit contact sensor does not detect the movement of actuator at the sensor while the polygon motor rotates.
Causes: • Defective paper transfer unit contact sensor • Defective paper transfer unit contact motor • Broken +24V fuse on PSU • Defective IOB
Remedy: 1. Check the connection between the paper transfer unit and PSU. 2. Replace the paper transfer unit contact sensor. 3. Replace the paper transfer unit contact motor. 4. Replace the +24V fuse on the PSU. 5. Replace the IOB.

Code: 460

Description: Separation power pack output error
An interrupt checks the status of the power pack every 20 ms. This SC is issued if the BICU detects a short in the power pack 10 times at D(ac).
Causes: • Damaged insulation on the high-voltage supply cable • Damaged insulation around the high-voltage power supply.
Remedy: 1. Replace the high-voltage supply cable. 2. Replace the high-voltage power supply unit. 3. Replace the IOB.

Code: 490

Description: Toner transport motor error
The LOCK signal is not detected for 2 seconds when the transport motor turns on.
Causes: • Toner transport motor overload • Disconnected or broken harness • Defective toner transport motor • Opened +24V fuse on the PSU • Defective interlock switch
Remedy: 1. Check or replace the harness. 2. Replace the toner transport motor. 3. Replace the +24V fuse on the PSU. 4. Replace the interlock switch.

Code: 491

Description: High voltage power: Drum/ development bias output error
An error signal is detected for 0.2 seconds when charging the drum or development.
Causes: • High voltage leak • Broken harness • Defective drum unit or development unit • Defective high voltage supply unit
Remedy: 1. Check or replace the harness. 2. Replace the drum unit or paper transfer unit. 3. Replace the high voltage supply unit.

Code: 492

Description: High voltage power: Image transfer/ paper transfer bias output error
An error signal is detected for 0.2 seconds when charging the separation, image transfer bet or paper transfer roller.
Causes: • High voltage leak • Broken harness • Defective image transfer belt unit or paper transfer unit • Defective high voltage supply unit
Remedy: 1. Check or replace the harness. 2. Replace the image transfer belt unit or paper transfer unit. 3. Replace the high voltage supply unit.

Code: 498

Description: Temperature and humidity sensor error 2
• The thermistor output of the temperature sensor was not within the prescribed range (0.5V to 4.2V). • The thermistor output of the humidity sensor was not within the prescribed range (0.01V to 2.4V).
Causes: • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective
Remedy: 1. Check the connector and harness. 2. Replace the temperature/humidity sensor.