Mã lỗi Ricoh Aficio MPC5002 — Trang 14/28
Code:
Tất cả lỗi (217)
101
120
121
141
142
144
161-001
161-002
165
195
202
203
204
210-01
210-02
210-03
210-04
220-01
220-02
220-03
220-04
230-01
230-02
230-03
230-04
231-01
231-02
231-03
231-04
240-01
240-02
240-03
240-04
270
285
312-01
312-02
312-03
312-04
360-01
360-02
360-03
360-04
361-01
361-02
361-03
361-04
362-01
362-02
362-03
362-04
370
390-01
390-02
390-03
390-04
396-01
396-02
396-03
396-04
441
442
443
452
460
490
491
492
498
501
502
503
504
505
520-01
520-02
530
531
532-01
532-02
533-01
534-01
535
538
540
541
542
543
544
545
547
549
551
552
553
554
555
557
559
561
562
563
564
569-00
569-01
571-00
572-02
573
574
581
591
610
620
621
622
623
632
633
634
635
636-01
636-02
636-11
637
640
641
650
651
652
653
670
672
681
682
687
720-24
720-25
720-30
720-41
720-42
720-44
720-52
720-53
720-58
720-59
720-70
720-71
720-80
720-81
722-10
722-14
722-17
724-31
724-32
724-33
724-38
724-41
724-42
724-44
724-70
724-85
770
791
792
816
817
819
821
822
823
824
833
834
838
840
841
842
850
851
853
854
855, 856
858
859
860
861
862
863
864
865
866
867
868
870
872
873
874
875
876
877
878
880
881
899
900
910...915
919
920
921
925
990
991
992
994
995
997
998
Description: Fusing shutter sensor error Fusing shutter plate home position sensor error is detected three consecutive times.
Causes: • Defective fusing shutter plate home position sensor • Defective connectors
Remedy: 1. Check or replace the harness of the fusing shutter plate home position sensor. 2. Replace the fusing shutter plate home position sensor.
Description: Pressure roller thermistor error: Center The center temperature of the pressure roller measured by the thermistor does not reach 0°C for 37 seconds.
Causes: • Loose connection of the thermistor • Defective thermistor
Remedy: 1. Check if the thermistor is firmly connected. 2. Replace the center thermistor.
Description: Pressure roller thermistor warm-up error: Center The center temperature of the pressure roller measured by the thermistor does not reach 20°C within 100 seconds after the heater turns on.
Causes: • Dirty thermopile lenses • Defective thermistor
Remedy: 1. Clean the thermopile lenses. 2. Replace the thermistor at the end of the pressure roller.
Description: Pressure roller overheat : Center (software error) The detected pressure roller temperature stays at 215°C or more for 1 second for 10 consecutive times.
Causes: • Defective IOB • Defective IPU
Remedy: 1. Replace the IOB. 2. Replace the IPU.
Description: Pressure roller overheat : Center (hardware error) The thermistor detects 220°C or more.
Causes: • Defective IOB • Defective IPU • Defective fusing control system
Remedy: 1. Replace the IOB. 2. Replace the IPU.
Description: NC sensor broken: Center The sensor detects -17°C or less for 100 seconds.
Causes: • Broken cables of thermopile or thermistor • Defective connection of connectors
Remedy: 1. Check and replace the connection of the cables and connectors.
Description: NC sensor broken: End The sensor detects -17°C or less for 100 seconds.
Causes: • Broken cables of thermopile or thermistor • Defective connection of connectors
Remedy: 1. Check and replace the connection of the cables and connectors.
Description: Mechanical counter error: K This SC is only for NA models. The machine detects the mechanical counter error when SP5-987-001 is set to "1 (ON)
Causes: • Disconnected mechanical counter • Defective mechanical counter
Remedy: 1. Check or replace the mechanical counter.