Description: Second duct fan error 1 The machine does not detect the fan motor lock signal for 100 ms while the second duct fan turns on.
Causes: • Disconnected harness • Overload on the second duct fan motor • Defective second duct motor • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the second duct fan. 3. Replace the IOB.
Code: 534-01
Description: Third duct fan error The machine does not detect the fan motor lock signal for 100 ms while the third duct fan turns on.
Causes: • Disconnected harness • Overload on the third duct fan motor • Defective third duct motor • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the third duct fan. 3. Replace the IOB.
Code: 535
Description: Paper exit fan error The machine does not detect the fan motor lock signal for 100 ms while the paper exit fan turns on.
Causes: • Disconnected harness • Overload on the paper exit fan motor • Defective paper exit motor • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the paper exit fan. 3. Replace the IOB.
Code: 538
Description: AC controller board fan error The machine does not detect the fan motor lock signal for 100 ms while the AC controller board fan turns on.
Causes: • Disconnected harness • Overload on the AC controller board fan motor • Defective AC controller board fan motor • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the AC controller board fan. 3. Replace the IOB.
Code: 540
Description: Fusing/Paper exit motor error The IOB does not receive the lock signal 100 ms after turning on the fusing/ paper exit motor.
Causes: • Motor overload • Defective fusing/paper exit motor • Shorted +24V fuse on the PSU
Remedy: 1. Check or replace the harness. 2. Replace the fusing/paper exit motor. 3. Replace the +24V fuse on the PSU.
Code: 541
Description: Heating roller thermopile error The temperature detected by the heating roller thermopile does not reach 0°C for 6 seconds.
Causes: • Loose connection of the heating roller thermopile • Defective heating roller thermopile • Defective thermopile
Remedy: 1. Check if the heating roller thermopile is firmly connected. 2. Replace the heating roller thermopile.
Code: 542
Description: Heating roller warm-up error 1 • The heating roller temperature does not reach 80°C for 20 seconds after the inverter turned on. • The center temperature of the heating roller does not reach the ready temperature for 90 seconds after the fusing lamp turned on.
Causes: • Dirty or defective thermopile
Remedy: 1. Check if the heating roller thermopile is firmly connected. 2. Replace the thermopile.
Code: 543
Description: Heating roller overheat: Center (software error) The detected fusing temperature stays at 215°C for 1 second for 10 consecutive times.