Description: Separation power pack output error
This SC is issued if the VBCU detects a short in the transfer power pack.
Causes: • Damaged insulation on the high-voltage supply cable (replace cable) • Damaged insulation around the transfer power pack
Code: SC465
Description: Image Transfer Roller End: K
The machine detected an abnormal reading of the resistance of the transfer roller because it is near the end of its service life.
Causes: • Check the connections between the transfer roller power pack the roller • Replace image transfer roller • Image transfer power pack defective
Code: SC466
Description: Image Transfer Roller End: M
The machine detected an abnormal reading of the resistance of the transfer roller because it is near the end of its service life.
Causes: • Check the connections between the transfer roller power pack the roller • Replace image transfer roller • Image transfer power pack defective
Code: SC467
Description: Image Transfer Roller End: C
The machine detected an abnormal reading of the resistance of the transfer roller because it is near the end of its service life.
Causes: • Check the connections between the transfer roller power pack the roller • Replace image transfer roller • Image transfer power pack defective
Code: SC468
Description: Image Transfer Roller End: Y
The machine detected an abnormal reading of the resistance of the transfer roller because it is near the end of its service life.
Causes: • Check the connections between the transfer roller power pack the roller • Replace image transfer roller • Image transfer power pack defective
Code: SC472
Description: ITB Bias Roller End
The machine detected an abnormal reading of the resistance of the ITB bias roller because it is near the end of its service life.
Causes: • Check the connections between the transfer power pack • Replace image transfer roller • Transfer power pack defective
Code: SC480
Description: Drum cleaning motor error: K
The drum cleaning motor failed to switch on (motor lock), or failed to reach the required speed within the prescribed time.
Causes: • Motor block by physical obstruction • Motor harness loose, broken, defective • Motor defective
Code: SC481
Description: Drum cleaning motor error: M
The drum cleaning motor failed to switch on (motor lock), or failed to reach the required speed within the prescribed time.
Causes: • Motor block by physical obstruction • Motor harness loose, broken, defective • Motor defective