Description: Scanner fan lock The fan motor next to the SIOB did not switch on within 10 sec. after the CPU issued the ON signal.
Causes: • Fan defective • Foreign object interfering with operation of fan • Motor harness loose, disconnected, or broken • SIOB defective
Code: SC181
Description: Scanner Fan Error: Lamp Stabilizer
The exposure lamp regulator fan is not rotating.
Causes: • Check the fan connections • Fan defective • Check SBU connection • Check SIOB connection • SBU defective • SIOB defective
Code: SC182
Description: Scanner Fan Error: Right Side
The fan located on the right side of the exposure unit is not rotating.
Causes: • Check the fan connections • Fan defective • Check SBU connection • Check SIOB connection • SBU defective • SIOB defective
Code: SC195
Description: Machine serial number error
The number registered for the machine serial number does not match.
Causes: • Confirm the correct serial number of the machine in the specifications • Important: When SC195 occurs, the serial number must be input. Please contact your technical supervisor.
Code: SC202
Description: Polygon motor error: ON timeout
The polygon mirror motor does not reach the targeted operating speed within the prescribed time
Causes: • Harness to polygon motor drive board disconnected, defective • Polygon motor defective • Polygon motor drive board defective • Polygon motor defective.
Code: SC203
Description: Polygon motor error: OFF timeout
The polygon mirror motor does leave the READY status within 3 seconds after the polygon motor switches off.
Causes: • Harness to polygon motor driver board disconnected, defective • Polygon motor defective • Polygon motor driver board defective • Polygon motor defective.
Code: SC204
Description: Polygon motor error: XSCRDY signal error
The polygon motor stopped operating while the LD unit was firing.
Causes: • Harness to polygon motor driver board disconnected, defective • Polygon motor defective • Polygon motor driver board defective