Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio MPC6000SP — Trang 26/36

Code: SC622

Description: PFB communication error
Communication between the VBCU and PFB was interrupted. (Communication status is monitored at 30 ms intervals.)
Causes: • Connection cable between the VBCU and PFB is disconnected, defective • VBCU defective • PFB defective

Code: SC624

Description: Mailbox-to-copier communication error
Communication between the mailbox and copier is interrupted. An ACK/NCK signal was not received within 100 ms after a data frame is sent and 3 retries failed.
Causes: • Mailbox cable disconnected, defective • Mailbox main board defective • VBCU defective • PSU defective

Code: SC625

Description: VBCU-DTMB (DMC1) communication error
Communication between the VBCU and DMC (main) was interrupted. An ACK/NAK signal was not received within 100 ms after a data frame was sent and three retries failed.
Causes: • Check the DTMB harness connections at the DTMB and VBCU • DTMB defective • PSU defective • VBCU defective • 5V power supply defective

Code: SC626

Description: VBCU-DTMB (DMC2) communication error
Communication between the VBCU and DMC (sub) was interrupted. An ACK/NAK signal was not received within 100 ms after a data frame was sent and three retries failed.
Causes: • Check the DTMB harness connections at the DTMB and VBCU • DTMB defective • VBCU defective • PSU defective

Code: SC627

Description: VBCU-DTMB (TMC) communication error
Communication between the VBCU and TMC was interrupted. An ACK/NAK signal was not received within 100 ms after a data frame was sent and three retries failed.
Causes: • DTMB harness loose, broken, defective • DTMB defective • VBCU defective • PSU defective

Code: SC687

Description: Memory address command error
The VBCU does not receive a memory address command from the controller 120 seconds after paper is in the position for registration.
Causes: • Turn the machine power off/on • Check the controller board connections • Controller defective

Code: SC701

Description: ARDF original pickup operation error
Even though the pickup motor is rotating clock-wise, the pickup roller home position sensor cannot detect the position of the pickup roller.
Causes: • Pickup roller HP sensor harness loose, disconnected, defective • Pickup roller HP sensor defective • Pickup motor harness loose, disconnected, defective • Pickup motor defective • ARDF control board defective

Code: SC705

Description: ARDF bottom plate lift motor
The bottom plate HP sensor did not detect the home position of the bottom plate after the bottom plate lift motor switches on and lowers the bottom plate. The bottom plate position sensor does not detect the position of the plate after the lift motor switches on and raises the bottom plate.
Causes: • ARDF feed motor disconnected, defective • Bottom plate HP sensor disconnected, defective • ARDF main board defective