Description: Z-Fold Memory Error
Several attempts to write to the Zfold memory failed.
Causes: • Turn the machine power off/on • EEPROM on Z-Folder main board defective
Code: SC817
Description: Boot loader error
The boot loader cannot read one of the following: self-diagnostic module, kernel, or one of the files of the root file system, or the check of one of these items on the system SD card failed.
Causes: • File or module on the system SD card is corrupted • File or module on the system SD card is illegal • Make sure that the system SD card is the one designed for the machine • Replace controller board.
Code: SC819
Description: Fatal kernel error
Due to a control error, a RAM overflow occurred during system processing. One of the following messages was displayed on the operation panel.
Causes: • System program defective • Controller board defective • Optional board defective • Replace controller firmware
Code: SC821
Description: Self-diagnostic error 1: ASIC
The ASIC provides the central point for the control of bus arbitration for CPU access, for option bus and SDRAM access, for SDRAM refresh, and for management of the internal bus gate.
Causes: • ASIC (controller board defective)
Code: SC822
Description: Self-diagnostic error 2: HDD
Causes:
Code: SC824
Description: Self-diagnostic error 3: NVRAM
NVRAM device does not exist, NVRAM device is damaged, NVRAM socket damaged