Các lỗi thường gặp

Code :
  • Code: SC351
  • Description: Developer Fill Error: M
    The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed.
  • Causes: • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see "Handling Problems with Developer Filling" under "PCU" in Section 3.
  • Code: SC352
  • Description: Developer Fill Error: C
    The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed.
  • Causes: • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see "Handling Problems with Developer Filling" under "PCU" in Section 3.
  • Code: SC353
  • Description: Developer Fill Error: Y
    The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed.
  • Causes: • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see "Handling Problems with Developer Filling" under "PCU" in Section 3.
  • Code: SC360
  • Description: TD sensor (Vt high) error: K
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
  • Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC361
  • Description: TD sensor (Vt high) error: M
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
  • Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC362
  • Description: TD sensor (Vt high) error: C
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
  • Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC363
  • Description: TD sensor (Vt high) error: Y
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
  • Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC364
  • Description: TD sensor (Vt low) error: K
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.