Description: ID sensor error: Development start voltage Y
The development start voltage in the development of the black, magenta, cyan, or yellow PCU is not within the correct range (+-150V)
Causes: • Toner density abnormal. Refer to the image troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual (Self-Check Error Codes 55 to 59, 61). • Potential sensor defective • LD unit not firing • ITB separation for CMY abnormal • Transfer power pack defective
Code: SC418
Description: LED error during Vsg adjustment
PWM value: Ifsg>3000 This means the current to the LED of the ID sensor is abnormal.
Causes: • ID sensor dirty • ID sensor defective
Code: SC420
Description: Potential sensor error: Vd Adjustment K
The development potential of the drum before exposure (Vd) cannot be adjusted to within +-8 V of the target voltage (-900V).
Description: Potential sensor error: Vd Adjustment K
The development potential of the drum before exposure (Vd) cannot be adjusted to within +-8 V of the target voltage (-900V).
Description: Potential sensor error: Vd Adjustment M
The development potential of the drum before exposure (Vd) cannot be adjusted to within +-8 V of the target voltage (-900V).
Description: Potential sensor error: Vd Adjustment C
The development potential of the drum before exposure (Vd) cannot be adjusted to within +-8 V of the target voltage (-900V).
Description: Potential sensor error: Vd Adjustment Y
The development potential of the drum before exposure (Vd) cannot be adjusted to within +-8 V of the target voltage (-900V).
Description: Potential sensor error 5: Vl adjustment K
Vpl could not be adjusted to within +-5V of the target Vpl after exposure of the ID sensor patterns.